Clinical SummaryRadiology · Musculoskeletal Imaging
 Narrative Review

Musculoskeletal Radiology · Imaging TechnologyFrom Silent Bone MRI to Fibroblast PET: Seven Advances Reshaping Musculoskeletal Imaging

Radiation-free bone imaging, quantitative cartilage biomarkers, AI that sharpens 1.5T scans and new molecular tracers are moving from research into the reporting room. A Japanese expert review weighs what each adds and what still stands in the way.

Originally Published25 December 2025
Time to Read11:00
Catalogue No.MRDC004
Published on MedED20 Novmber 2026
Keywords Zero Echo Time MRI Quantitative MRI Deep Learning Reconstruction Whole-Body MRI FAPI PET Weight-Bearing CT
§ References
About this summary

Originally Published: 25 December 2025 (online)

MedED Summary Published: [DD Month 2026]

Author: The Medical Education Network

Catalogue Number: [CATALOGUE]

Platform: www.meded.co.za

This summary is based on an open-access article distributed under the terms of the CC BY licence, which permits unrestricted use, distribution and reproduction in any medium. AI may have been used to assist in preparing this summary. The content is intended as an overview only and does not replace the original research article. Medical Education Network strongly encourages all members to review the original study before forming clinical opinions or making decisions.

Original Research

Read the full open-access paper

This document is based on original research published in Magnetic Resonance in Medical Sciences:

Ide, S., Aoki, T., Kurokawa, R., Yanagawa, M., Saida, T., Sugawara, S., Nishioka, K., Oda, S., Watabe, T., Hirata, K., Ito, R., Ueda, D., Takumi, K., Honda, M., Sakata, A., Kawamura, M., Sofue, K., Iima, M., & Naganawa, S. (2026). Recent advances in musculoskeletal radiology: Bridging innovation and clinical application. Magnetic Resonance in Medical Sciences, 25(1). https://doi.org/10.2463/mrms.rev.2025-0150

The full paper includes case images for each technique and seven summary tables listing clinical applications, limitations and example acquisition parameters.

Copyright

Licence and attribution

This summary is based on an open-access article published under a Creative Commons Attribution (CC BY 4.0) licence, which permits unrestricted use, distribution and reproduction in any medium, provided the original work is properly cited. Copyright in the original article remains with the authors (© 2026 Japanese Society for Magnetic Resonance in Medicine).

It is an independent interpretation prepared by the Medical Education Network and has not been reviewed or endorsed by the study authors or the publisher. Charts have been redrawn from data reported in the original article and the studies it cites.

The summary does not replace the original research, and members are strongly encouraged to review the original study before forming clinical opinions or making decisions. Please see the Disclaimer at the end of this page for more information.

© 2026 Medical Education Network. All rights reserved.

Key TakeawayOf the seven advances in MRI, CT, PET and artificial intelligence reviewed, three are closest to changing how musculoskeletal imaging is requested and read. CT-like bone MRI, such as zero echo time imaging, can show cortical bone and calcification without ionising radiation; whole-body diffusion MRI offers radiation-free staging of bone metastases, myeloma and lymphoma; and deep learning reconstruction can lift 1.5T image quality to rival 3T. The others, including quantitative cartilage mapping, MR spectroscopy, new PET tracers and weight-bearing CT, still need multicentre validation and standardised protocols before routine use.
Quick ViewIde et al. 2026
Design
Narrative review by radiologists from 16 Japanese institutions
Scope
Seven domains: CT-like contrast MRI, quantitative MRI, AI, MR spectroscopy, whole-body MRI, novel PET tracers and advanced CT
Audience
Radiologists, orthopaedic surgeons, rheumatologists and oncologists who request or interpret MSK imaging
Strongest signals
Whole-body diffusion MRI for skeletal malignancy (pooled per-patient sensitivity 95%, specificity 92%); 1.5T MRI with deep learning reconstruction outperforming conventional 3T in a volunteer study
Main gaps
Limited multicentre validation, variable vendor availability, lack of protocol standardisation, and cost
Original research
Ide, S., Aoki, T., Kurokawa, R., et al. (2026). Recent advances in musculoskeletal radiology: Bridging innovation and clinical application. Magnetic Resonance in Medical Sciences, 25(1). https://doi.org/10.2463/mrms.rev.2025-0150
Bottom line
MSK imaging is shifting from shape to function, metabolism and load, but much of it is not yet ready for every department.
01

Clinical Context

Radiographs and CT remain the workhorses for bone, and MRI for cartilage, ligament and marrow. Each has long had a blind spot: CT shows little of soft tissue, while conventional MRI cannot capture tissues whose signal decays almost instantly, such as cortical bone, tendon and fibrocartilage.1

Ide and colleagues, writing for the Japanese Society for Magnetic Resonance in Medicine, bring together the developments now closing those gaps. They organise the field into seven areas and, for each, set out what the technique shows, where it has been applied clinically, its practical limits and example acquisition settings.1

Questions This Review AddressesWhich new MRI, CT, PET and AI techniques add real diagnostic value in musculoskeletal practice? Where is the evidence strong enough to change practice, and what still holds back routine adoption?
02

Seeing Bone on MRI

Two sequences now produce bone images on MRI with a contrast resembling CT. Zero echo time (ZTE) imaging begins sampling the signal effectively at the moment of excitation, so cortical bone and calcification, normally dark on MRI, become visible; inverting the greyscale then gives a radiograph- or CT-like picture. The authors illustrate its use for erosions in rheumatoid arthritis, heterotopic ossification, ossification of the posterior longitudinal ligament and Paget’s disease.1

FRACTURE, a multi-echo gradient-echo technique, reaches a similar result by subtracting the last echo from a combination of earlier ones. Its appeal is that it runs on standard hardware.1

No head-to-head study has compared the two, but the review identifies several advantages for ZTE. It is almost silent, which matters for children and fetal imaging: the authors cite noise levels of roughly 69 dB, close to the ambient level of the room, against 90 to 110 dB for conventional sequences.1,2 ZTE is also less prone than FRACTURE to bright signal from CSF, air, haemorrhage, cyst walls or vascular lesions that can be mistaken for bone, copes better with metal, and offers higher signal-to-noise and efficiency.1

CautionOn ZTE, gas and calcification can look alike, and acquisition is longer than CT. Not every manufacturer offers the sequence, and some implementations need upgraded gradient hardware.1

The authors argue that these techniques do more than stand in for CT: combined with soft-tissue contrast and diffusion imaging in the same examination, they suit children, patients needing repeated follow-up and others for whom radiation is a concern.1

03

Measuring Tissue Health

Quantitative MRI replaces visual impression with numbers that reflect tissue composition, and can reveal damage before morphology changes.1

Three Quantitative TechniquesIde et al. 20261
T2 mapping
The most established. Reflects water content and collagen organisation in cartilage and menisci; adds sensitivity for early cartilage degeneration and monitoring after repair. Standard acquisition takes 5–10 minutes, cut to about 6 with accelerated sequences.
3D T1rho mapping
Tracks proteoglycan loss, a candidate early marker of osteoarthritis. Combined with ultrashort echo readouts it also reaches tendons, ligaments and the osteochondral junction. Under 5 minutes, but implementation differs between vendors.
UTE–T2* mapping
Uses echo times of a few hundredths of a millisecond to quantify fibrocartilage, menisci, tendons and ligaments. Thought to reflect collagen microstructure rather than water, so it suits load-bearing tissues. Requires dedicated sequences.
In practice
The three are complementary: T2 for early cartilage change, T1rho for matrix depletion, UTE–T2* for short-T2 structures conventional MRI cannot see.

One example from the authors’ own work shows the functional potential: in a healthy volunteer, T2* values of the triangular fibrocartilage fell when the wrist was pronated, consistent with the tissue responding to load and tensile strain.1

04

AI in the Scanner and the Report

Deep learning reconstruction

At 1.5T with AI reconstruction, knee images outscored conventional 3T.

Deep learning reconstruction (DLR) suppresses noise so that scans can be faster, sharper or both, and fewer need repeating.1 In a volunteer study cited by the review, Akai and colleagues scanned the knees of 27 healthy volunteers at 1.5T and 3T with similar protocols. With commercial DLR applied, the 1.5T images had less noise, clearer menisci and ligaments and higher overall diagnostic acceptability than the 3T images.3

The authors point out that this matters where 3T is unavailable, costly or contraindicated, for example in patients whose implanted devices are approved only for 1.5T.1 DLR also helps low-signal sequences such as STIR and T1 fast spin echo, small-joint imaging of the fingers when combined with radial sampling, and diffusion imaging of small intradiscal abscesses.1

 

Diagnostic support and language models

Convolutional networks are being applied to fracture detection and to grading anterior cruciate ligament injury. In one study the review describes, a transfer-learning model graded early (grade 1 and 2) ACL injuries more accurately than radiologists.1 The same work exposed a typical pitfall: fluid around an intact ligament led the model to call a complete tear.1

On the reporting side, Doi and colleagues trained a deep-learning language model on 1,749 Japanese free-text radiology reports to flag patients with bone metastases. Its precision averaged 0.912, with an AUC of 0.968, and the authors propose it as an automated alert to prompt follow-up and help prevent skeletal-related events.1,4

CautionDLR can over-smooth images or create artefacts, and its benefit varies by vendor and training data. Diagnostic models need large annotated datasets, local validation and continued radiologist oversight.1
05

Metabolism, Whole-Body and Molecular Imaging

MR spectroscopy

Proton spectroscopy adds a metabolic dimension to tumour assessment. A choline peak at 3.2 ppm favours malignancy and has been reported in high-grade soft-tissue sarcomas and in bone sarcomas including Ewing sarcoma and osteosarcoma, whereas many benign lesions show little choline. A falling choline level may indicate response to chemotherapy, and its absence after surgery can help separate scar from recurrence.1 Phosphorus-31 spectroscopy measures muscle energetics; in sarcopenia it has shown impaired mitochondrial function and lower phosphocreatine. It needs a dedicated coil and benefits from higher field strength.1

Whole-body MRI

Whole-body MRI, particularly with diffusion-weighted imaging, provides radiation-free staging across the skeleton and soft tissues in a single examination.1 The review draws on several meta-analyses. For skeletal malignancy, diffusion-weighted MRI reached a pooled per-patient sensitivity of 95% and specificity of 92%.1,5 For treatment response in multiple myeloma, whole-body MRI was more sensitive than FDG PET/CT (87% vs 64%) but less specific (57% vs 82%), suggesting the two are complementary.6 For Hodgkin lymphoma, it agreed closely with FDG PET/CT for both nodal and extranodal staging.1,7 International consensus already regards it as the imaging reference standard for marrow involvement in myeloma, including smouldering disease.1

Pooled diagnostic performance of whole-body MRI from meta-analyses cited in the review.
Sensitivity and specificity reported in the original studies or as cited by Ide et al. Indications, populations and reference standards differ, so the bars should not be compared across categories. Hover or tap a bar for the 95% CI where reported. Sources: Ide et al. 2026; Liu et al. 2015; Rama et al. 2022; Spijkers et al. 2023; Madsen et al. 2025.1,5–7,9

Beyond oncology, whole-body protocols map inflammation across axial and peripheral joints and entheses in spondyloarthritis and psoriatic arthritis, and assist with multifocal conditions, among them muscular dystrophies, SAPHO syndrome and chronic recurrent multifocal osteomyelitis, including choosing biopsy sites.1 Scoring systems for inflammatory disease are still being standardised.1

Novel PET tracers

Fibroblast activation protein inhibitor (FAPI) tracers target the activated fibroblasts that drive synovitis and fibrosis. In a prospective study of patients with rheumatoid arthritis, Luo and colleagues found that all 244 affected joints identified across both scans were positive on gallium-68 FAPI PET/CT, with higher uptake in the most affected joint than on FDG PET/CT (mean SUVmax 9.54 vs 5.85), and FAPI uptake tracked clinical and laboratory disease activity.8 A fluorine-18 FAPI agent has also revealed subclinical fibrotic muscle involvement in sarcoidosis that FDG PET missed.1

In prostate cancer, a prospective head-to-head study of 160 men with newly diagnosed high-risk disease found similar accuracy for bone metastases with fluorine-18 PSMA PET/CT (sensitivity 0.98, specificity 0.99) and sodium fluoride PET/CT (0.91 and 1.00). The investigators concluded that a separate sodium fluoride scan may be unnecessary when PSMA PET/CT shows no bone disease.9

95% / 92%
Pooled per-patient sensitivity and specificity of diffusion-weighted MRI for skeletal malignancy1,5
9.54 vs 5.85
Mean SUVmax of the most affected joint in rheumatoid arthritis on FAPI vs FDG PET/CT8
06

CT Under Load and in Colour

Weight-bearing CT images joints in three dimensions under physiological load. Using upright CT, Sasaki and colleagues showed that the three-dimensional mechanical axis of the lower limb shifts medially and posteriorly as knee osteoarthritis advances, and in Kellgren–Lawrence grades 3 and 4 it lies outside the joint altogether.10 The review notes applications in flatfoot, hallux valgus and ankle instability, though scanners remain scarce and positioning must be standardised.1

Dual-energy CT separates urate, calcium pyrophosphate and hydroxyapatite deposits, depicts fine tendon structure and shows marrow oedema and occult fractures. DLR combined with metal artefact reduction improves pelvic CT in patients with hip prostheses.1

07

Interpreting the Evidence

The review’s strength is its breadth: it gives clinicians a single map of the technologies now entering musculoskeletal practice, with practical acquisition detail for each. As a narrative review, however, it does not describe a systematic search or appraise study quality, and much of the evidence it presents comes from single-centre studies, small volunteer cohorts and illustrative cases, several from the authors’ own institutions.1

The authors set out four priorities: careful validation, regulatory approval and integration of AI into clinical systems; prospective multicentre testing of sequences such as ZTE and UTE; standardised acquisition and analysis so that quantitative biomarkers can be compared between centres; and broader access, since many of these techniques depend on specific hardware, software and budgets.1

Practice PointWhere available, consider whether a radiation-free MRI technique can answer the clinical question before requesting CT or PET, particularly in children and in patients who need repeated imaging.1
08

For South African Practitioners

Scope note: The review includes no South African data and does not consider resource-limited settings. The local context below is drawn from separately cited South African research.

Access to MRI is the first constraint. A six-year audit of the Western Cape public sector found that its population grew by 8% between 2013 and 2018 while the number of public MRI units stayed the same, so access fell from 0.65 to 0.59 scanners per million people. The authors cite a figure of 0.33 scanners per million for the South African public sector as a whole.11

In that context, the techniques most likely to matter locally are those that extract more from existing equipment. The review’s evidence that deep learning reconstruction can bring 1.5T image quality up to 3T standards,3 and that a single whole-body MRI can stand in for several radiation-based studies,1 is directly relevant where 3T scanners and PET are concentrated in a few centres. Vendor-specific sequences and dedicated hardware, by contrast, will be harder to adopt widely.

Practical ImplicationsCheck which of these sequences and reconstruction options your local scanners already support, as some may be available as software upgrades. Reserve scarce MRI and PET capacity for questions where the added information will change management.
Clinical TakeoutMusculoskeletal imaging is gaining radiation-free bone imaging, quantitative tissue biomarkers, AI-enhanced image quality and targeted molecular tracers. The authors conclude that validation in multicentre studies and protocol standardisation are now the main steps between these innovations and routine practice.
§

References

  1. Ide S, Aoki T, Kurokawa R, Yanagawa M, Saida T, Sugawara S, et al. Recent advances in musculoskeletal radiology: Bridging innovation and clinical application. Magn Reson Med Sci. 2026;25(1). doi: 10.2463/mrms.rev.2025-0150
  2. Alibek S, Vogel M, Sun W, Winkler D, Baker CA, Burke M, et al. Acoustic noise reduction in MRI using Silent Scan: An initial experience. Diagn Interv Radiol. 2014;20(4):360–363. doi: 10.5152/dir.2014.13458
  3. Akai H, Yasaka K, Sugawara H, Tajima T, Akahane M, Yoshioka N, et al. Commercially available deep-learning-reconstruction of MR imaging of the knee at 1.5T has higher image quality than conventionally-reconstructed imaging at 3T: A normal volunteer study. Magn Reson Med Sci. 2023;22(3):353–360. doi: 10.2463/mrms.mp.2022-0020
  4. Doi K, Takegawa H, Yui M, Anetai Y, Koike Y, Nakamura S, et al. Deep learning-based detection of patients with bone metastasis from Japanese radiology reports. Jpn J Radiol. 2023;41(8):900–908. [DOI to confirm]
  5. Liu LP, Cui LB, Zhang XX, Cao J, Chang N, Tang X, et al. Diagnostic performance of diffusion-weighted magnetic resonance imaging in bone malignancy: Evidence from a meta-analysis. Medicine (Baltimore). 2015;94(45):e1998. doi: 10.1097/MD.0000000000001998
  6. Rama S, Suh CH, Kim KW, Durieux JC, Ramaiya NH, Tirumani SH. Comparative performance of whole-body MRI and FDG PET/CT in evaluation of multiple myeloma treatment response: Systematic review and meta-analysis. AJR Am J Roentgenol. 2022;218(4):602–613. [DOI to confirm]
  7. Spijkers S, Littooij AS, Beishuizen A, Lam MGEH, Nievelstein RAJ. A meta-analysis on the diagnostic performance of whole-body MRI for the initial staging of Hodgkin lymphoma in children and adults using FDG-PET/CT as a reference standard. EJC Paediatr Oncol. 2023;1:100016. [DOI to confirm]
  8. Luo Y, Pan Q, Zhou Z, Li M, Wei Y, Jiang X, et al. 68Ga-FAPI PET/CT for rheumatoid arthritis: A prospective study. Radiology. 2023;307(3):e222052. doi: 10.1148/radiol.222052
  9. Madsen C, Fuglø D, Pedersen M, Broholm R, Østergren PB, Bisbjerg R, et al. Prospective head-to-head comparison of 18F-PSMA PET/CT and 18F-NaF PET/CT for assessing bone metastases in 160 patients with newly diagnosed high-risk prostate cancer. J Nucl Med. 2025;66(2):223–229. doi: 10.2967/jnumed.124.268275
  10. Sasaki R, Kaneda K, Yamada Y, Niki Y, Nakamura M, Nagura T, et al. Extra-articular location of the three-dimensional mechanical axis in advanced knee osteoarthritis: An upright computed tomography study. Jpn J Radiol. 2023;41(12):1405–1413. doi: 10.1007/s11604-023-01468-1
  11. Parak Y, Davis R, Barnard M, et al. A 6-year audit of public-sector MR utilisation in the Western Cape province of South Africa. S Afr J Radiol. 2022;26(1):a2464. doi: 10.4102/sajr.v26i1.2464
First Published25 December 2025
JournalMagnetic Resonance in Medical Sciences
CopyrightThis is an open access article distributed under the terms of the Creative Commons CC BY license
CategoryRadiology
Sub-CategoryMusculoskeletal Imaging
Summary PublisherMedical Education Network
Disclaimer & Fact-Checking Policy

Disclaimer. This is a summary of published research and does not replace the original study or local treatment guidelines. Every effort has been made to attribute quotes and content correctly. Where possible, all information has been independently verified. The Medical Education Network bears no responsibility for any inaccuracies which may occur from the use of third-party sources. AI may have been used to assist in preparing this summary. All efforts have been made to validate the content against the original material; however, inaccuracies may occur. The Medical Education Network urges all practitioners to review the original material as their clinical reference. The Medical Education Network bears no responsibility where these clinical summaries are used as a proxy for the original research. If you have any queries regarding this article contact us

Fact-checking Policy. The Medical Education Network makes every effort to review and fact-check the articles used as source material in our summaries and original material. We have strict guidelines in relation to the publications we use as our source data, favouring peer-reviewed research wherever possible. Every effort is made to ensure that the information contained here accurately reflects the original material. Should you find inaccuracies or out-of-date content or have any additional issues with our articles, please make use of the Contact Us form to notify us.