Imaging AI has matured fastest in diagnostic radiology, where data are plentiful. A new Mayo Clinic review maps how far it has reached into vascular interventional radiology, from EVAR planning and bleed detection to predicting who will respond to TACE.
Source review originally published: 5 January 2026 (online); October 2026 issue, Journal of Imaging Informatics in Medicine
Published on MedED: [DD Month 2026]
Type of article: Clinical narrative review
Author: The Medical Education Network
Catalogue Number: [CATALOGUE]
Platform: www.meded.co.za
AI may have been used to assist in preparing this article. The content is intended as an overview only and does not replace the original sources. Medical Education Network strongly encourages all members to review the original material before forming clinical opinions or making decisions.
This article is based on a narrative review published in the Journal of Imaging Informatics in Medicine:
Mukhtar, H., Ganjizadeh, A., Misra, A., Kane, J., Wang, P., Singh, P. G., Lemieux, A., Baranwal, G., Kilari, S., Erickson, B. J., & Misra, S. (2026). Imaging-based artificial intelligence in vascular and interventional radiology: A narrative review. Journal of Imaging Informatics in Medicine, 39(5), 3810–3819. https://doi.org/10.1007/s10278-025-01803-0 (Epub 5 January 2026; PMID: 41491740; PMCID: PMC13694673)
Where the review reports the findings of an individual study, that study is cited directly. Figures are as reported in the review and were checked against the original publications where these were accessible. Where the review’s reference details differ from the published record, the published record has been used.
South African context draws on SAHPRA (2025) and Idrees et al. (South African Journal of Radiology, 2025).
The source review is published open access under a Creative Commons Attribution 4.0 International (CC BY 4.0) licence, © The Author(s) 2025. This article is an independent interpretation of that review by the Medical Education Network and has not been reviewed or endorsed by its authors. Changes have been made: the material has been summarised, reorganised and supplemented with additional sources.
This article is compiled from a variety of resources researched and compiled by the Medical Education Network. It is in no way presented as an original work. Every effort has been made to correctly attribute quotes and content, and quoted passages remain the property of their respective publishers.
Please see the Disclaimer at the end of this page for more information.
© 2026 Medical Education Network. All rights reserved.
Diagnostic radiology has been the proving ground for imaging AI because it produces large, digitised and fairly standardised datasets on which deep neural networks train well. Vascular IR has had far less to work with: case volumes are smaller, and procedures, devices and imaging protocols vary widely between operators and centres.1 The review authors nonetheless see a wide reach for AI across the procedural pathway, from patient selection beforehand, through image interpretation during the case, to prognosis afterwards.1
Mukhtar, Ganjizadeh and colleagues searched PubMed, Embase and Web of Science for original English-language studies published up to April 2025 in which an AI model used imaging input at any stage of a vascular IR procedure and had a direct bearing on patient care. A study was included when at least two of three reviewers agreed. The included work was grouped by modality and by task: segmentation, detection, prediction and prognostication, and a miscellaneous group that includes image registration and frame interpolation.1
The review is organised by modality. This narrative regroups its findings by when in the patient’s course the tool would be used, which is how a referring clinician or interventionalist is more likely to meet them.
Pre-procedural sizing is labour-intensive and, for the thoracic aorta, lacks an agreed method for taking the measurements from CT. Saitta and colleagues trained a 3D U-Net on 395 CT scans and tested it on 70, embedding it in a pipeline that segments the thoracic aorta, identifies the proximal landing zones and returns the geometric measurements needed for TEVAR planning. It achieved a mean Dice score of 0.95 and generalised to nine cases of thoracic aortic aneurysm.2
For infrarenal disease, the commercial PRAEVAorta software performs fully automatic volumetric segmentation of the aneurysm sac, lumen and thrombus. Caradu and colleagues reported a Dice similarity coefficient of 0.95 against physician-controlled manual segmentation, with significantly shorter processing time.3
Duplex ultrasound is quick and radiation-free, but interpretation of spectral waveform morphology varies considerably between observers. Normahani and colleagues trained machine-learning classifiers on Doppler waveforms sampled at the ankle in patients with diabetes; their best logistic regression model identified peripheral artery disease with an AUC of 0.93.5
In the renal circulation, a pilot study took 200 patients with unilateral atherosclerotic renal artery stenosis that had been confirmed at angiography and required stenting, using the contralateral normal kidney as each patient’s control. A one-dimensional convolutional network trained on the spectral waveforms detected the stenosed side with an AUC of 0.97.4 Readers should note that this study comes from the review’s own senior authors.1,4
Several models aim to sharpen patient selection. In uterine fibroid embolisation, Luo and colleagues trained a ResNet on pre-procedural MRI from 409 patients with 727 fibroids. The model trained on contrast-enhanced T1 images predicted clinical outcome with a test accuracy of 0.847, against an average of 0.722 for the radiologists who reviewed the same cases.6
Post-TIPS hepatic encephalopathy is another target. Cheng and colleagues built a random-forest radiomics model from pre-TIPS contrast-enhanced CT. It achieved an AUC of 0.887 in the test cohort, while a model built on clinical parameters reached 0.649.7 The review notes a second study from the same group, using radiomic features of visceral adipose tissue, that also outperformed clinical prediction.1
Intra-procedural AI works on fluoroscopy and DSA. Much of the device-segmentation work the review describes, covering guidewires, catheters and stents, has been developed on phantoms and simulations rather than in patients.1 Three studies stand out because they target decisions the operator makes in real time.
Min and colleagues developed InterNet, a two-stage deep-learning system that localises the region of interest and then the bleeding site on emergency abdominal DSA. With the model’s assistance, a reader’s AUC for identifying active arterial bleeding rose from 0.759 to 0.803, and interpretation time per DSA sequence fell from 84.88 to 43.78 seconds.8
Li and colleagues trained a model on intra-operative fluoroscopy to identify a “No-Go” landing zone during EVAR, defined as the segment where the stent graft would cover the lowest renal artery. The review reports an accuracy of 0.97 and a specificity of 0.99.9
Tang and colleagues approached radiation exposure from a different angle: acquire fewer frames and let a neural network synthesise the missing ones. Using 1,634 IR sequences from 167 paediatric patients, the interpolated frames reached mean peak signal-to-noise ratios of 44.94 dB for angiographic, 34.84 dB for subtraction and 33.82 dB for fluoroscopic sequences, with structural similarity indices of 0.984, 0.919 and 0.775 respectively.10 Image fidelity was lowest for fluoroscopic sequences.
The review also describes deep-learning motion compensation for vascular cone-beam CT, and registration of intra-procedural CBCT with pre-procedural MRI to guide TACE.1
Post-EVAR follow-up is among the most studied applications in the review. Talebi and colleagues trained a U-Net on CTA from 50 post-EVAR patients with endoleak and 20 without. Against subspecialist interpretation, it detected endoleak with an accuracy of 95%, precision of 90% and recall of 100%; the authors reported performance similar to subspecialists and better than generalists.11
Hu and colleagues asked whether endoleaks could be detected without contrast. In 216 patients, 64 of whom had endoleaks, twelve machine-learning models built on radiomic features of the aneurysm sac on unenhanced CT averaged an AUC of 0.86 and an accuracy of 81%.12 That offers a possible alternative to contrast-enhanced surveillance, though not yet a substitute.
Surveillance typically becomes less frequent as time passes, so identifying high-risk patients early could justify a more intensive schedule for them.1 The longest-running example is an artificial neural network from Karthikesalingam and colleagues, which used 19 morphological features from pre-operative CT angiography to sort patients into low- and high-risk groups.13
More recent models use radiomics and texture analysis. Ding and colleagues applied texture analysis to the first post-EVAR CT in 99 patients; a multilayer perceptron using grey-level co-occurrence matrix features predicted later sac expansion with an accuracy of 85.17% and an AUC of 0.90, outperforming clinical and conventional imaging features combined.14 In a single-centre cohort of 711 patients, Wang and colleagues used radiomic features from pre-operative CTA to predict outcome after EVAR, with their logistic regression model reaching an AUC of 0.93 and an F1 score of 0.91.15
After TEVAR for Stanford type B dissection, negative aortic remodelling is the leading cause of late reintervention. Zhou and colleagues’ point-cloud neural network, combining CTA with clinical features, predicted negative remodelling with an AUC of 0.884 and reintervention with an AUC of 0.836.1,16
IVC filters are easily lost to follow-up, particularly when patients move between providers. Gomes and colleagues trained a U-Net to segment filters on abdominopelvic CT (Dice 0.82) and built it into an algorithm that flagged scans containing a filter with an accuracy of 92.22%.17 On plain radiographs, Ni and colleagues’ network distinguished 14 filter types with an F1 score of 0.97, and displayed heatmaps of the image features it relied on.18 Line-tip position is a similar problem: an early two-network system for PICC tip detection located the tip with a mean absolute distance of 3.10 mm from ground truth.19
Predicting response to TACE and TARE is the most crowded field in the review, with models built on CT, MRI and DSA. In a multicentre CT study, Peng and colleagues’ pyradiomics signature predicted initial TACE response in HCC with AUCs of 0.917 in the discovery cohort and 0.902 and 0.911 in two validation sets.20 Zhang and colleagues’ DSA-Net read DSA video from 605 patients with intermediate-stage HCC, reaching an accuracy of 78.2% in internal validation and 75.1% in external validation.21
For Y-90 radiation segmentectomy, Wagstaff and colleagues tested a convolutional network ensemble against voxel-based dosimetry in 77 patients with 103 lesions. The ensemble predicted complete response with a higher F1 score (0.72 vs 0.2), accuracy (0.65 vs 0.60) and sensitivity (1.0 vs 0.11).22
The review authors are candid about the limits of the field. Large, high-quality and diverse datasets are scarce; many of the included studies relied on small samples or a single centre; and the variability of interventional procedures, patient populations and imaging protocols makes models hard to transfer.1 Models trained on imbalanced data risk overfitting and may underperform in under-represented subgroups and rare scenarios, which is why the authors call for rigorous external testing and continuous refinement.1
Interpretability is a second barrier. Deep-learning models can post strong metrics while their reasoning remains opaque to the clinician who has to act on the output, and the authors argue that explainable-AI techniques and human oversight are needed to build trust.1 Few of the included studies show what the model attends to, though the IVC filter classifier is an example of one that does.18
The review also sets out the regulatory picture in the United States, where most of these tools would be classed as Software as a Medical Device. Adaptive algorithms that keep learning after approval need predetermined change control plans and robust post-market surveillance, and unresolved questions remain about data governance, equitable access and liability when AI-assisted care goes wrong.1
Looking ahead, the authors identify real-time intra-procedural decision support, feeding back on device position, anatomy and procedural risk, as the most promising direction, alongside AI-driven simulation and augmented-reality guidance for training.1
Scope note: The review contains no South African data and does not consider how these models would perform in local patient populations, on local imaging equipment or within local workflows. The points below come from separate South African sources.
The regulatory framework is now in place locally. In 2025 the South African Health Products Regulatory Authority (SAHPRA) issued a communication to industry setting out the regulatory requirements for AI- and machine-learning-enabled medical devices in South Africa, with a medical device definition aligned to that of the International Medical Device Regulators Forum.23 The review’s discussion of FDA pathways therefore has a direct local counterpart.
The workforce context is just as relevant. In a 2024 national survey of radiology registrars, Idrees and colleagues found that 40% of the 100 respondents were interested in IR as a subspeciality, but only 27% reported adequate exposure to it, 17% had none, and only 9% had a structured curriculum. South Africa has not yet established a nationally recognised IR subspeciality certification.24
Taken together, the review shows imaging AI reaching every stage of vascular IR. Segmentation and surveillance tasks show the most consistent performance; outcome prediction is the most active; and intra-procedural guidance is the most ambitious, with much of it still at the phantom or single-centre stage.1 Radiomics combined with conventional machine learning has proved a recurring and productive approach to predicting response and stratifying risk after EVAR, TACE, TARE and TIPS.1
For the practising interventionalist, the question is less whether these models perform well in the studies that built them, and more whether they will perform on the next patient, from a different scanner, in a different hospital. Until external and prospective validation catches up with development, these tools are best seen as decision support that still needs testing in practice.
Disclaimer. This article is compiled from a variety of resources researched and compiled by the Medical Education Network. It is in no way presented as an original work. AI may have been used to assist in preparing this article. Every effort has been made to correctly attribute quotes and content. Where possible, all information has been independently verified. The Medical Education Network bears no responsibility for any inaccuracies which may occur from the use of third-party sources. The Medical Education Network urges all practitioners to review the original material as their clinical reference. If you have any queries regarding this article contact us
Fact-checking Policy. The Medical Education Network makes every effort to review and fact-check the articles used as source material in our summaries and original material. We have strict guidelines in relation to the publications we use as our source data, favouring peer-reviewed research wherever possible. Every effort is made to ensure that the information contained here accurately reflects the original material. Should you find inaccuracies or out-of-date content or have any additional issues with our articles, please make use of the Contact Us form to notify us.