Clinical ReviewRadiology · Interventional Radiology
 Narrative Review

Artificial Intelligence · Vascular IRAI in the Angio Suite: What the Imaging Evidence Shows Before, During and After Vascular Intervention

Imaging AI has matured fastest in diagnostic radiology, where data are plentiful. A new Mayo Clinic review maps how far it has reached into vascular interventional radiology, from EVAR planning and bleed detection to predicting who will respond to TACE.

Originally Published5 January 2026
Time to Read13:00
Catalogue No.MRDC002
Published on MedED20 November 2026
Keywords Artificial Intelligence Deep Learning Radiomics EVAR TACE Interventional Radiology
§ References
About this article

Source review originally published: 5 January 2026 (online); October 2026 issue, Journal of Imaging Informatics in Medicine

Published on MedED: [DD Month 2026]

Type of article: Clinical narrative review

Author: The Medical Education Network

Catalogue Number: [CATALOGUE]

Platform: www.meded.co.za

AI may have been used to assist in preparing this article. The content is intended as an overview only and does not replace the original sources. Medical Education Network strongly encourages all members to review the original material before forming clinical opinions or making decisions.

Sources

Where this review draws from

This article is based on a narrative review published in the Journal of Imaging Informatics in Medicine:

Mukhtar, H., Ganjizadeh, A., Misra, A., Kane, J., Wang, P., Singh, P. G., Lemieux, A., Baranwal, G., Kilari, S., Erickson, B. J., & Misra, S. (2026). Imaging-based artificial intelligence in vascular and interventional radiology: A narrative review. Journal of Imaging Informatics in Medicine, 39(5), 3810–3819. https://doi.org/10.1007/s10278-025-01803-0 (Epub 5 January 2026; PMID: 41491740; PMCID: PMC13694673)

Where the review reports the findings of an individual study, that study is cited directly. Figures are as reported in the review and were checked against the original publications where these were accessible. Where the review’s reference details differ from the published record, the published record has been used.

South African context draws on SAHPRA (2025) and Idrees et al. (South African Journal of Radiology, 2025).

Copyright

Attribution

The source review is published open access under a Creative Commons Attribution 4.0 International (CC BY 4.0) licence, © The Author(s) 2025. This article is an independent interpretation of that review by the Medical Education Network and has not been reviewed or endorsed by its authors. Changes have been made: the material has been summarised, reorganised and supplemented with additional sources.

This article is compiled from a variety of resources researched and compiled by the Medical Education Network. It is in no way presented as an original work. Every effort has been made to correctly attribute quotes and content, and quoted passages remain the property of their respective publishers.

Please see the Disclaimer at the end of this page for more information.

© 2026 Medical Education Network. All rights reserved.

Key TakeawayImaging AI in vascular IR performs most consistently where the task is measurement or surveillance: automated aortic segmentation for EVAR and TEVAR planning, endoleak detection, and flagging of indwelling devices. Outcome models for EVAR, TEVAR, TIPS and liver-directed therapy frequently beat clinical scores in the studies that built them, but most rest on small or single-centre datasets and have yet to show they hold up in external, prospective use.
At a GlanceAI in Vascular IR
Source
  1. Mukhtar, H., Ganjizadeh, A., Misra, A., Kane, J., Wang, P., Singh, P. G., Lemieux, A., Baranwal, G., Kilari, S., Erickson, B. J., & Misra, S. (2026). Imaging-based artificial intelligence in vascular and interventional radiology: A narrative review. Journal of Imaging Informatics in Medicine, 39(5), 3810–3819. https://doi.org/10.1007/s10278-025-01803-0 (Epub 5 January 2026; PMID: 41491740; PMCID: PMC13694673)
Scope
Vascular IR only; neurointervention and interventional cardiology excluded1
Modalities
CT, MRI, fluoroscopy and DSA, ultrasound, plain radiography, multimodal1
Strongest signals
Aortic segmentation Dice 0.95;2,3 endoleak detection on CTA at subspecialist level;11 renal artery stenosis on Doppler AUC 0.974
Main limitation
Small, single-centre datasets; risk of bias and overfitting; limited interpretability1
Bottom line
Promising decision support at every stage of the procedure, with external validation still the gap.
01

Why Vascular IR Has Lagged Behind

Diagnostic radiology has been the proving ground for imaging AI because it produces large, digitised and fairly standardised datasets on which deep neural networks train well. Vascular IR has had far less to work with: case volumes are smaller, and procedures, devices and imaging protocols vary widely between operators and centres.1 The review authors nonetheless see a wide reach for AI across the procedural pathway, from patient selection beforehand, through image interpretation during the case, to prognosis afterwards.1

Mukhtar, Ganjizadeh and colleagues searched PubMed, Embase and Web of Science for original English-language studies published up to April 2025 in which an AI model used imaging input at any stage of a vascular IR procedure and had a direct bearing on patient care. A study was included when at least two of three reviewers agreed. The included work was grouped by modality and by task: segmentation, detection, prediction and prognostication, and a miscellaneous group that includes image registration and frame interpolation.1

The review is organised by modality. This narrative regroups its findings by when in the patient’s course the tool would be used, which is how a referring clinician or interventionalist is more likely to meet them.

About the evidence baseAs a narrative review, the paper reports each study’s headline metrics without pooling them, and its methods describe no formal quality or risk-of-bias appraisal. The figures below come from different cohorts, reference standards and validation designs, so they indicate what each model achieved in its own setting and should not be compared head-to-head.1
02

Before the Procedure: Planning and Patient Selection

Automating aortic measurement

Pre-procedural sizing is labour-intensive and, for the thoracic aorta, lacks an agreed method for taking the measurements from CT. Saitta and colleagues trained a 3D U-Net on 395 CT scans and tested it on 70, embedding it in a pipeline that segments the thoracic aorta, identifies the proximal landing zones and returns the geometric measurements needed for TEVAR planning. It achieved a mean Dice score of 0.95 and generalised to nine cases of thoracic aortic aneurysm.2

For infrarenal disease, the commercial PRAEVAorta software performs fully automatic volumetric segmentation of the aneurysm sac, lumen and thrombus. Caradu and colleagues reported a Dice similarity coefficient of 0.95 against physician-controlled manual segmentation, with significantly shorter processing time.3

Doppler waveforms as AI input

Duplex ultrasound is quick and radiation-free, but interpretation of spectral waveform morphology varies considerably between observers. Normahani and colleagues trained machine-learning classifiers on Doppler waveforms sampled at the ankle in patients with diabetes; their best logistic regression model identified peripheral artery disease with an AUC of 0.93.5

In the renal circulation, a pilot study took 200 patients with unilateral atherosclerotic renal artery stenosis that had been confirmed at angiography and required stenting, using the contralateral normal kidney as each patient’s control. A one-dimensional convolutional network trained on the spectral waveforms detected the stenosed side with an AUC of 0.97.4 Readers should note that this study comes from the review’s own senior authors.1,4

Predicting who will benefit

Several models aim to sharpen patient selection. In uterine fibroid embolisation, Luo and colleagues trained a ResNet on pre-procedural MRI from 409 patients with 727 fibroids. The model trained on contrast-enhanced T1 images predicted clinical outcome with a test accuracy of 0.847, against an average of 0.722 for the radiologists who reviewed the same cases.6

Post-TIPS hepatic encephalopathy is another target. Cheng and colleagues built a random-forest radiomics model from pre-TIPS contrast-enhanced CT. It achieved an AUC of 0.887 in the test cohort, while a model built on clinical parameters reached 0.649.7 The review notes a second study from the same group, using radiomic features of visceral adipose tissue, that also outperformed clinical prediction.1

03

In the Angio Suite

Intra-procedural AI works on fluoroscopy and DSA. Much of the device-segmentation work the review describes, covering guidewires, catheters and stents, has been developed on phantoms and simulations rather than in patients.1 Three studies stand out because they target decisions the operator makes in real time.

Finding the bleed

Min and colleagues developed InterNet, a two-stage deep-learning system that localises the region of interest and then the bleeding site on emergency abdominal DSA. With the model’s assistance, a reader’s AUC for identifying active arterial bleeding rose from 0.759 to 0.803, and interpretation time per DSA sequence fell from 84.88 to 43.78 seconds.8

43.8 s
Interpretation time per emergency DSA sequence with InterNet assistance, down from 84.9 s8
0.803
Reader AUC for active abdominal arterial bleeding with the model, against 0.759 without8
CautionInterNet is an aid to the operator, not a replacement. In its evaluation set, the system on its own reached a recall of 0.7 with a precision of 53% for bleeding sites.8

Landing the graft

Li and colleagues trained a model on intra-operative fluoroscopy to identify a “No-Go” landing zone during EVAR, defined as the segment where the stent graft would cover the lowest renal artery. The review reports an accuracy of 0.97 and a specificity of 0.99.9

Cutting the dose

Tang and colleagues approached radiation exposure from a different angle: acquire fewer frames and let a neural network synthesise the missing ones. Using 1,634 IR sequences from 167 paediatric patients, the interpolated frames reached mean peak signal-to-noise ratios of 44.94 dB for angiographic, 34.84 dB for subtraction and 33.82 dB for fluoroscopic sequences, with structural similarity indices of 0.984, 0.919 and 0.775 respectively.10 Image fidelity was lowest for fluoroscopic sequences.

The review also describes deep-learning motion compensation for vascular cone-beam CT, and registration of intra-procedural CBCT with pre-procedural MRI to guide TACE.1

04

After the Procedure: Surveillance and Response

EVAR surveillance

Post-EVAR follow-up is among the most studied applications in the review. Talebi and colleagues trained a U-Net on CTA from 50 post-EVAR patients with endoleak and 20 without. Against subspecialist interpretation, it detected endoleak with an accuracy of 95%, precision of 90% and recall of 100%; the authors reported performance similar to subspecialists and better than generalists.11

Hu and colleagues asked whether endoleaks could be detected without contrast. In 216 patients, 64 of whom had endoleaks, twelve machine-learning models built on radiomic features of the aneurysm sac on unenhanced CT averaged an AUC of 0.86 and an accuracy of 81%.12 That offers a possible alternative to contrast-enhanced surveillance, though not yet a substitute.

Stratifying long-term risk

Surveillance typically becomes less frequent as time passes, so identifying high-risk patients early could justify a more intensive schedule for them.1 The longest-running example is an artificial neural network from Karthikesalingam and colleagues, which used 19 morphological features from pre-operative CT angiography to sort patients into low- and high-risk groups.13

Findings from Karthikesalingam et al.External validation, 5 years13
Freedom from aortic complications
95.9% low-risk vs 67.9% high-risk
Freedom from limb complications
99.3% low-risk vs 92.0% high-risk
Survival
87.9% low-risk vs 79.3% high-risk

More recent models use radiomics and texture analysis. Ding and colleagues applied texture analysis to the first post-EVAR CT in 99 patients; a multilayer perceptron using grey-level co-occurrence matrix features predicted later sac expansion with an accuracy of 85.17% and an AUC of 0.90, outperforming clinical and conventional imaging features combined.14 In a single-centre cohort of 711 patients, Wang and colleagues used radiomic features from pre-operative CTA to predict outcome after EVAR, with their logistic regression model reaching an AUC of 0.93 and an F1 score of 0.91.15

After TEVAR for Stanford type B dissection, negative aortic remodelling is the leading cause of late reintervention. Zhou and colleagues’ point-cloud neural network, combining CTA with clinical features, predicted negative remodelling with an AUC of 0.884 and reintervention with an AUC of 0.836.1,16

Keeping track of indwelling devices

IVC filters are easily lost to follow-up, particularly when patients move between providers. Gomes and colleagues trained a U-Net to segment filters on abdominopelvic CT (Dice 0.82) and built it into an algorithm that flagged scans containing a filter with an accuracy of 92.22%.17 On plain radiographs, Ni and colleagues’ network distinguished 14 filter types with an F1 score of 0.97, and displayed heatmaps of the image features it relied on.18 Line-tip position is a similar problem: an early two-network system for PICC tip detection located the tip with a mean absolute distance of 3.10 mm from ground truth.19

Liver-directed therapy

Predicting response to TACE and TARE is the most crowded field in the review, with models built on CT, MRI and DSA. In a multicentre CT study, Peng and colleagues’ pyradiomics signature predicted initial TACE response in HCC with AUCs of 0.917 in the discovery cohort and 0.902 and 0.911 in two validation sets.20 Zhang and colleagues’ DSA-Net read DSA video from 605 patients with intermediate-stage HCC, reaching an accuracy of 78.2% in internal validation and 75.1% in external validation.21

For Y-90 radiation segmentectomy, Wagstaff and colleagues tested a convolutional network ensemble against voxel-based dosimetry in 77 patients with 103 lesions. The ensemble predicted complete response with a higher F1 score (0.72 vs 0.2), accuracy (0.65 vs 0.60) and sensitivity (1.0 vs 0.11).22

CautionHeadline figures can mask weak spots. DSA-Net’s sensitivity fell to 50.5% in its external cohort,21 and the Y-90 ensemble’s perfect sensitivity came with an overall accuracy of 0.65.22
AUCs reported by selected detection and prediction models in the review, with the one clinical comparator shown in orange. Each is the figure reported for that model; where a study gave several cohorts, the test or validation figure is shown.
Reported area under the ROC curve. Tasks, cohorts, reference standards and validation designs differ between studies, so the bars are not a ranking. Sources: Mukhtar et al., 2025;4 Normahani et al., 2022;5 Cheng et al., 2022;7 Hu et al., 2024;12 Ding et al., 2020;14 Wang et al., 2023;15 Zhou et al., 2024;16 Peng et al., 2022.20
05

Reading the Evidence Critically

The review authors are candid about the limits of the field. Large, high-quality and diverse datasets are scarce; many of the included studies relied on small samples or a single centre; and the variability of interventional procedures, patient populations and imaging protocols makes models hard to transfer.1 Models trained on imbalanced data risk overfitting and may underperform in under-represented subgroups and rare scenarios, which is why the authors call for rigorous external testing and continuous refinement.1

Interpretability is a second barrier. Deep-learning models can post strong metrics while their reasoning remains opaque to the clinician who has to act on the output, and the authors argue that explainable-AI techniques and human oversight are needed to build trust.1 Few of the included studies show what the model attends to, though the IVC filter classifier is an example of one that does.18

The review also sets out the regulatory picture in the United States, where most of these tools would be classed as Software as a Medical Device. Adaptive algorithms that keep learning after approval need predetermined change control plans and robust post-market surveillance, and unresolved questions remain about data governance, equitable access and liability when AI-assisted care goes wrong.1

“Continued clinician AI expert collaboration will be crucial for responsible deployment…”1

Looking ahead, the authors identify real-time intra-procedural decision support, feeding back on device position, anatomy and procedural risk, as the most promising direction, alongside AI-driven simulation and augmented-reality guidance for training.1

06

What This Means in South Africa

Scope note: The review contains no South African data and does not consider how these models would perform in local patient populations, on local imaging equipment or within local workflows. The points below come from separate South African sources.

The regulatory framework is now in place locally. In 2025 the South African Health Products Regulatory Authority (SAHPRA) issued a communication to industry setting out the regulatory requirements for AI- and machine-learning-enabled medical devices in South Africa, with a medical device definition aligned to that of the International Medical Device Regulators Forum.23 The review’s discussion of FDA pathways therefore has a direct local counterpart.

The workforce context is just as relevant. In a 2024 national survey of radiology registrars, Idrees and colleagues found that 40% of the 100 respondents were interested in IR as a subspeciality, but only 27% reported adequate exposure to it, 17% had none, and only 9% had a structured curriculum. South Africa has not yet established a nationally recognised IR subspeciality certification.24

A note on transferabilitySome of the tools in the review were built partly with under-resourced settings in mind: the InterNet authors, for example, describe their system as a way to help where expert radiologists are scarce, as in rural and community hospitals.8 That rationale is plainly relevant where IR expertise is thin. But none of these models has been tested on South African patients or scanners, and the generalisability concerns the review raises apply with particular force to populations absent from the training data.1
07

In Conclusion

Taken together, the review shows imaging AI reaching every stage of vascular IR. Segmentation and surveillance tasks show the most consistent performance; outcome prediction is the most active; and intra-procedural guidance is the most ambitious, with much of it still at the phantom or single-centre stage.1 Radiomics combined with conventional machine learning has proved a recurring and productive approach to predicting response and stratifying risk after EVAR, TACE, TARE and TIPS.1

For the practising interventionalist, the question is less whether these models perform well in the studies that built them, and more whether they will perform on the next patient, from a different scanner, in a different hospital. Until external and prospective validation catches up with development, these tools are best seen as decision support that still needs testing in practice.

§

References

  1. Mukhtar, H., Ganjizadeh, A., Misra, A., Kane, J., Wang, P., Singh, P. G., Lemieux, A., Baranwal, G., Kilari, S., Erickson, B. J., & Misra, S. (2026). Imaging-based artificial intelligence in vascular and interventional radiology: A narrative review. Journal of Imaging Informatics in Medicine, 39(5), 3810–3819. https://doi.org/10.1007/s10278-025-01803-0 (Epub 5 January 2026; PMID: 41491740; PMCID: PMC13694673)
  2. Saitta, S., Sturla, F., Caimi, A., Riva, A., Palumbo, M. C., Nano, G., Votta, E., Della Corte, A., Glauber, M., Chiappino, D., Marrocco-Trischitta, M. M., & Redaelli, A. (2022). A deep learning-based and fully automated pipeline for thoracic aorta geometric analysis and planning for endovascular repair from computed tomography. Journal of Digital Imaging, 35(2), 226–239. https://doi.org/10.1007/s10278-021-00535-1
  3. Caradu, C., Spampinato, B., Vrancianu, A. M., Bérard, X., & Ducasse, E. (2021). Fully automatic volume segmentation of infrarenal abdominal aortic aneurysm computed tomography images with deep learning approaches versus physician controlled manual segmentation. Journal of Vascular Surgery, 74(1), 246–256.e6. https://doi.org/10.1016/j.jvs.2020.11.036
  4. Mukhtar, H., Rassoulinejad-Mousavi, S. M., Faghani, S., Erickson, B. J., & Misra, S. (2025). Pilot study of using machine learning to detect atherosclerotic renal artery stenosis from spectral Doppler waveforms. Kidney International Reports, 10(4), 1213–1222. https://doi.org/10.1016/j.ekir.2025.01.012
  5. Normahani, P., Sounderajah, V., Mandic, D., & Jaffer, U. (2022). Machine learning-based classification of arterial spectral waveforms for the diagnosis of peripheral artery disease in the context of diabetes: A proof-of-concept study. Vascular Medicine, 27(5), 450–456. https://doi.org/10.1177/1358863X221105113
  6. Luo, Y.-H., Xi, I. L., Wang, R., Abdallah, H. O., Wu, J., Vance, A. Z., Chang, K., Kohi, M., Jones, L., Reddy, S., Zhang, Z.-S., Bai, H. X., & Shlansky-Goldberg, R. (2020). Deep learning based on MR imaging for predicting outcome of uterine fibroid embolization. Journal of Vascular and Interventional Radiology, 31(6), 1010–1017.e3. https://doi.org/10.1016/j.jvir.2019.11.032
  7. Cheng, S., Hu, G., Xue, H., Jin, Z., & Wang, Z. (2022). CT-based radiomics model for preoperative prediction of hepatic encephalopathy after transjugular intrahepatic portosystemic shunt. British Journal of Radiology, 95(1133), 20210792. [DOI to confirm]
  8. Min, X., Feng, Z., Gao, J., Chen, S., Zhang, P., Fu, T., Shen, H., & Wang, N. (2022). InterNet: Detection of active abdominal arterial bleeding using emergency digital subtraction angiography imaging with two-stage deep learning. Frontiers in Medicine, 9, 762091. https://doi.org/10.3389/fmed.2022.762091
  9. Li, A., Javidan, A. P., Namazi, B., Madani, A., & Forbes, T. L. (2024). Development of an artificial intelligence tool for intraoperative guidance during endovascular abdominal aortic aneurysm repair. Annals of Vascular Surgery, 99, 96–104. [DOI to confirm]
  10. Tang, Z., Xiong, Q., Wu, X., Xu, T., Shi, Y., Xu, X., Xu, J., & Wang, R. (2024). Radiation reduction for interventional radiology imaging: A video frame interpolation solution. Insights into Imaging, 15(1), 42. https://doi.org/10.1186/s13244-024-01620-z
  11. Talebi, S., Madani, M. H., Madani, A., Chien, A., Shen, J., Mastrodicasa, D., Fleischmann, D., Chan, F. P., & Mofrad, M. R. K. (2020). Machine learning for endoleak detection after endovascular aortic repair. Scientific Reports, 10(1), 18343. https://doi.org/10.1038/s41598-020-74936-7
  12. Hu, G., Ding, N., Wang, Z., & Jin, Z. (2024). Unenhanced computed tomography radiomics help detect endoleaks after endovascular repair of abdominal aortic aneurysm. European Radiology, 34(3), 1647–1658. https://doi.org/10.1007/s00330-023-10000-y
  13. Karthikesalingam, A., Attallah, O., Ma, X., Bahia, S. S., Thompson, L., Vidal-Diez, A., Choke, E. C., Bown, M. J., Sayers, R. D., Thompson, M. M., & Holt, P. J. (2015). An artificial neural network stratifies the risks of reintervention and mortality after endovascular aneurysm repair; a retrospective observational study. PLoS ONE, 10(7), e0129024. https://doi.org/10.1371/journal.pone.0129024
  14. Ding, N., Hao, Y., Wang, Z., Xuan, X., Kong, L., Xue, H., & Jin, Z. (2020). CT texture analysis predicts abdominal aortic aneurysm post-endovascular aortic aneurysm repair progression. Scientific Reports, 10(1), 12268. https://doi.org/10.1038/s41598-020-69226-1
  15. Wang, Y., Zhou, M., Ding, Y., Li, X., Zhou, Z., Xie, T., Shi, Z., & Fu, W. (2023). A radiomics model for predicting the outcome of endovascular abdominal aortic aneurysm repair based on machine learning. Vascular, 31(4), 654–663. [DOI to confirm]
  16. Zhou, M., Luo, X., Wang, X., Xie, T., Wang, Y., Shi, Z., Wang, M., & Fu, W. (2024). Deep learning prediction for distal aortic remodeling after thoracic endovascular aortic repair in Stanford type B aortic dissection. Journal of Endovascular Therapy, 31(5), 910–918. [DOI to confirm]
  17. Gomes, R., Kamrowski, C., Mohan, P. D., Senor, C., Langlois, J., & Wildenberg, J. (2022). Application of deep learning to IVC filter detection from CT scans. Diagnostics, 12(10), 2475. https://doi.org/10.3390/diagnostics12102475
  18. Ni, J. C., Shpanskaya, K., Han, M., Lee, E. H., Do, B. H., Kuo, W. T., Yeom, K. W., & Wang, D. S. (2020). Deep learning for automated classification of inferior vena cava filter types on radiographs. Journal of Vascular and Interventional Radiology, 31(1), 66–73. https://doi.org/10.1016/j.jvir.2019.05.026
  19. Lee, H., Mansouri, M., Tajmir, S., Lev, M. H., & Do, S. (2018). A deep-learning system for fully-automated peripherally inserted central catheter (PICC) tip detection. Journal of Digital Imaging, 31(4), 393–402. https://doi.org/10.1007/s10278-017-0025-z
  20. Peng, J., Lu, F., Huang, J., Zhang, J., Gong, W., Hu, Y., & Wang, J. (2022). Development and validation of a pyradiomics signature to predict initial treatment response and prognosis during transarterial chemoembolization in hepatocellular carcinoma. Frontiers in Oncology, 12, 853254. https://doi.org/10.3389/fonc.2022.853254
  21. Zhang, L., Jiang, Y., Jin, Z., Jiang, W., Zhang, B., Wang, C., Wu, L., Chen, L., Chen, Q., Liu, S., You, J., Mo, X., Liu, J., Xiong, Z., Huang, T., Yang, L., Wan, X., Wen, G., Han, X. G., . . . Zhang, S. (2022). Real-time automatic prediction of treatment response to transcatheter arterial chemoembolization in patients with hepatocellular carcinoma using deep learning based on digital subtraction angiography videos. Cancer Imaging, 22(1), 23. https://doi.org/10.1186/s40644-022-00457-3
  22. Wagstaff, W. V., Villalobos, A., Gichoya, J., & Kokabi, N. (2023). Using deep learning to predict treatment response in patients with hepatocellular carcinoma treated with Y90 radiation segmentectomy. Journal of Digital Imaging, 36(3), 1180–1188. https://doi.org/10.1007/s10278-022-00762-0
  23. South African Health Products Regulatory Authority. (2025). Regulatory requirements of artificial intelligence and machine learning (AI/ML) enabled medical devices (Communication to industry MD08-2025/2026). https://www.sahpra.org.za/?p=18572
  24. Idrees, S., Christofides, N., & Moodley, H. (2025). An analysis of interventional radiology training needs of radiology registrars in South Africa. South African Journal of Radiology, 29(1), a3192. https://doi.org/10.4102/sajr.v29i1.3192
Published on MedED20 November 2026
Type of ArticleClinical Narrative Review
Catalogue No.MRD002
CategoryRadiology
Sub-CategoryInterventional Radiology
PublisherMedical Education Network
Disclaimer & Fact-Checking Policy

Disclaimer. This article is compiled from a variety of resources researched and compiled by the Medical Education Network. It is in no way presented as an original work. AI may have been used to assist in preparing this article. Every effort has been made to correctly attribute quotes and content. Where possible, all information has been independently verified. The Medical Education Network bears no responsibility for any inaccuracies which may occur from the use of third-party sources. The Medical Education Network urges all practitioners to review the original material as their clinical reference. If you have any queries regarding this article contact us

Fact-checking Policy. The Medical Education Network makes every effort to review and fact-check the articles used as source material in our summaries and original material. We have strict guidelines in relation to the publications we use as our source data, favouring peer-reviewed research wherever possible. Every effort is made to ensure that the information contained here accurately reflects the original material. Should you find inaccuracies or out-of-date content or have any additional issues with our articles, please make use of the Contact Us form to notify us.

↑ Back to top
Rapid SSL

The Medical Education Network
Powered by eLecture, a VisualLive Solution